Part code:
MDH11JDC9JA2AN – R2 DIGITAL 136-174MHZ 5W NON-DISPLAY
MDH11YDC9JA2AN – R2 DIGITAL 403-480MHZ 4W NON-DISPLAY
* Motorola Solutions ALT testing.
** 26.5 hours runtime, dependant on TX/RX.
Transmitter Specifications
4FSK digital modulation
12.5 kHz Data: 7K60F1D and 7K60FXD
12.5 kHz Voice: 7K60F1E and 7K60FXE
Combination: 7K60F1W
Digital protocol
ETSI TS 102 361-1, -2, -3DMR Tier II
Conducted/radiated spurious emissions (TIA603E)
< -36 dBm for < 1 GHz ; < -30 dBm for > 1 GHz
Adjacent channel power
>60 dB @ 12.5kHz / >70 dB @ 20/25 kHz
Frequency stability
± 0.5 ppm
Modulation limiting
± 2.5 kHz @ 12.5 kHz / ± 4.0 kHz @ 20 kHz /
± 5.0 kHz @ 25 kHz
Receiver Specifications
Analogue sensitivity (12dB SINAD)
0.18 μV (typical)
Digital sensitivity (5% BER)
0.16 μV (typical)
Conducted/radiated spurious emissions (TIA603E)
< -57 dBm
Intermodulation (TIA603E)
> 70 dB
Adjacent channel selectivity
(TIA603A) -1T> 60 dB @ 12.5 kHz / > 70dB @ 20/25 kHz
(TIA603E) -2T> 55 dB @ 12.5 kHz / > 70dB @ 20/25 kHz
Spurious rejection (TIA603D)
> 70 dB
Frequency stability
± 0.5 ppm
Audio Specifications
Digital vocoder type
AMBE+2
Audio response
TIA603E
Audio output power (Rated/Max)
1 W / 3 W
Audio distortion at rated power
3% (typical)
Maximum speech loudness (ISO 532B)
101 phon
Hum and noise
-40 dB @ 12.5 kHz / -45 dB @ 20/25 kHz
Environmental Specifications
Operating temperature
-30 °C to 60 °C
Storage temperature
-40 °C to 85 °C
Thermal shock
Per MIL-STD 810C, D, E, F, G, H
Humidity
Per MIL-STD 810C, D, E, F, G, H
Electrostatic discharge
IEC 61000-4-2 Level 4
Dust and water intrusion
IEC60529 IP55
Salt fog
Per MIL-STD 810C/D/E/F/G/H
Packaging test
Per MIL-STD 810C/D/E/F/G/H
Through Motorola Application Partners, Radiocoms Systems support a cost-effective portfolio of MOTOTRBO software applications to further enhance your sites operational goals – lone worker, alarm handling and job ticketing streamline efficiency whilst aligning with operational procedures, assisting in industry compliance and ultimately creating a safer work environment.
If you would like further information, or to discuss your requirements onsite:
Book An Appointment | Arrange A Quotation | Call 033 3939 0022
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |