Skip to main content

www.radiocoms.co.uk

What are ATEX-approved two-way radios?

In oil and gas, chemical processing, utilities, manufacturing, fuel storage and other hazardous sites, communication has to work without adding risk. A standard handheld radio may be fine in an office, warehouse or retail setting. But in an area where flammable gases, vapours, mists or combustible dusts may be present, electrical equipment needs to be suitable for that environment.

That is where an ATEX radio comes in. ATEX-approved radios are designed and certified for use in potentially explosive atmospheres, giving teams a safer way to communicate in areas where a spark, hot surface or unsuitable accessory could create a serious hazard.

A petrochemical plant where ATEX-approved two-way radios are used.

 

For businesses operating in hazardous areas, ATEX two-way radios are not just about clearer voice communication. They form part of a wider safety system that may include lone worker alerts, emergency calls, location services, gas detection alerts, control room software and group communications.

What ATEX means for radio users

An ATEX radio is a radio that has been assessed and marked for use in specific hazardous zones, so it is not enough for a device to be rugged, waterproof or industrial-grade. The radio must also be certified for the type of explosive atmosphere and the level of risk present on site. Within the Radiocoms range, options such as the Motorola range can support different hazardous-area communication requirements, depending on the site, system, and certification needed.

ATEX is often used as shorthand for the European framework covering equipment and protective systems intended for use in potentially explosive atmospheres. In Great Britain, requirements for equipment placed on the market sit under the Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations 2016.

For employers, ATEX also links closely with DSEAR, the Dangerous Substances and Explosive Atmospheres Regulations 2002. DSEAR requires employers to assess and control fire and explosion risks from dangerous substances. Where hazardous areas are identified, employers need to classify those areas into zones and select equipment that is suitable for those zones.

ATEX radios and labelling

ATEX labelling tells you where a device can be used. A compliant device should carry the “Ex” mark, the relevant conformity marking, equipment group and category, and details linked to gas or dust use, temperature class and protection type.

This labelling matters because not all ATEX radios are certified for the same environments. A radio suitable for one zone may not be suitable for another. Accessories also matter. Batteries, remote speaker microphones, headsets, earpieces, chargers and carry cases should be approved for use with that radio in the intended environment.

Using a non-approved accessory can undermine the safety case, even if the radio itself is certified.

Choosing a Radio for the Correct ATEX Zone

For gases, vapours and mists, and for combustible dust environments, the key consideration is selecting radios that are certified for the specific zone classification on your site.

For higher-risk areas such as Zone 0 and Zone 20, where explosive atmospheres may be present continuously or for long periods, intrinsically safe radios with the highest level of certification are required. Devices such as the Hytera HP79X Ex, Hytera PD795Ex and Motorola Solutions DP4801Ex are typically specified for these environments, as they are designed to operate safely under the most demanding hazardous conditions.

For Zone 1 and Zone 21 areas, where explosive atmospheres may occur during normal operation, many of the same high-spec ATEX radios are suitable, offering a balance of safety certification and advanced communication features. Radios like the Entel DTEx range and Motorola Solutions R7Ex models are often used here, depending on system requirements and user preferences.

For lower-risk areas such as Zone 2 and Zone 22, where explosive atmospheres are less likely and only present for short periods, a wider range of ATEX-certified radios may be appropriate. In some cases, businesses may choose devices with slightly lower certification levels, provided they still meet the requirements of the zone and site risk assessment.

In all cases, the final choice should be based on the certified rating of the radio, the accessories being used, and the specific hazards identified on site.

Once zones are defined, radios must be selected with the correct certification for those environments. For example, Motorola Solutions offers a range of ATEX-certified radios designed for use in higher-risk zones, including the MOTOTRBO R7Ex ATEX NKP and MOTOTRBO™ R7Ex FKP for digital radio systems, which provide enhanced audio performance and usability in demanding environments. For organisations operating on TETRA networks, the Motorola Solutions MTP8500Ex is designed for use in hazardous areas while supporting mission-critical communications.

What makes a two-way radio “ATEX approved”?

An ATEX-approved radio is designed to reduce ignition risk. Depending on the certification and design, this can include limiting electrical and thermal energy, controlling surface temperatures, protecting internal components, and using materials that are suitable for hazardous areas.

Many ATEX-approved two-way radios also include features needed in high-risk operational settings, such as:

The right specification depends on the environment. For example, an offshore maintenance team may need intrinsically safe radios with emergency alerts and noise-cancelling audio accessories. A fuel storage site may need wide-area coverage, group calling and dispatcher visibility. A chemical plant may need alarms from gas detection devices to reach supervisors quickly. 

For organisations using Motorola Solutions technology, Radiocoms can also advise on ATEX models such as the MOTOTRBO R7Ex FKP digital two-way radio and MOTOTRBO R7Ex NKP digital two-way radio, helping teams compare radio options based on coverage, usability, keypad preference and operational needs.

The difference between ATEX and standard two-way radios

A standard two-way radio may be rugged and reliable, but that does not make it safe for a hazardous area. Standard radios are not normally designed or certified to prevent ignition in explosive atmospheres. Battery contacts, switches, charging points, electronics, or accessories may all create risks if used in the wrong area.

ATEX radios are built and tested for defined hazardous zones. They are also supplied with instructions and markings that show how they should be used. That includes which accessories are approved and any operating restrictions that apply. Where a TETRA network is in use, an ATEX-certified device such as the Motorola Solutions MTP8500Ex TETRA ATEX radio may be considered as part of the wider radio system design.

This difference is why procurement should never be based on radio performance alone. Coverage, battery life and audio quality matter, but certification must come first in a zoned hazardous area.

Why standard radios can be dangerous in explosive environments

In a hazardous area, the concern is not whether a standard radio works. It may transmit perfectly well. The concern is whether it could become an ignition source.

Explosive atmospheres can be created by flammable gas leaks, solvent vapours, fine dusts or mist. If the atmosphere ignites, the result can be fire, explosion, injury, loss of assets and downtime. Standard equipment may also put employers at odds with their risk assessment, zoning requirements and site procedures.

For this reason, workers should only use equipment that has been approved for the area they are entering.

The industries that require intrinsically safe communications

ATEX-approved radios are often used in sectors such as:

  • Oil and gas
  • Petrochemical processing
  • Energy and utilities
  • Fuel storage and distribution
  • Chemical manufacturing
  • Ports and marine operations
  • Wastewater treatment
  • Food, grain and powder handling
  • Paint spraying and coatings
  • Distilleries and other alcohol production sites
  • COMAH-regulated facilities

Radiocoms supports hazardous-area communication projects across oil and gas and related industrial settings. You can read more on our Oil and Gas ATEX page.

Are ATEX radios required by law?

There is no single rule that says every business must use an ATEX radio. The requirement depends on the risk assessment, the hazardous area classification and the equipment being used in that area.

However, where workers are using radios in zoned hazardous areas, employers should select equipment that is suitable for those zones. In Great Britain, new equipment placed on the market for potentially explosive atmospheres must meet the relevant product safety requirements and carry the correct marking and documentation.

The practical answer is simple: if your team needs radio communication inside a classified hazardous area, standard devices should not be used as a substitute for certified equipment.

Can ATEX radios be used with body-worn cameras or headsets?

Yes, but only if the full device set-up is suitable for the hazardous area. Headsets, microphones and other accessories should be approved for use with the chosen ATEX radio and the relevant zone.

Body-worn cameras need the same level of care. A camera used in a standard security or facilities environment may not be suitable for an explosive atmosphere. If video, audio and radio communications are all required, the equipment list should be reviewed as one system, not as separate purchases.

Gas detection can also be integrated with radio communications. For example, the Honeywell and Motorola connected safety system pairs Honeywell portable gas detectors, including devices such as the BW™ Solo, BW™ Ultra and MicroRAE™ monitors, with MOTOTRBO radios. 

These detectors can monitor a range of atmospheric hazards, including combustible gases, oxygen levels and toxic gases, while automatically transmitting alarm and status information through the radio network. Gas detector alerts can be sent to Honeywell Safety Suite, giving safety teams real-time visibility of gas readings, worker location, device status and emergency alarms. This connected approach helps improve incident response, supports lone worker protection and enables more effective monitoring of personnel operating in hazardous environments.

Choosing the right ATEX radio for your business

Choosing ATEX radios starts with the site, not the catalogue. Before selecting devices, confirm the hazardous zones, substances present, working patterns, PPE, coverage needs and emergency response process.

A good review should consider:

  • Which ATEX zones the radios need to cover.
  • Whether gas, vapour, mist or dust is the main risk.
  • Indoor, outdoor, offshore or remote coverage requirements.
  • Noise levels and PPE.
  • Lone worker, man-down and emergency alert needs.
  • GPS, indoor location or dispatcher visibility.
  • Approved accessories.
  • Integration with gas detection, alarms or control room systems.
  • OFCOM licensing and radio network design.
  • Maintenance, inspection and user training.

Radiocoms can help assess your requirements, design the radio network and recommend suitable ATEX-approved radios for your working environment.

This may include comparing different device families, from Hytera and Entel ATEX handsets to Motorola Solutions MOTOTRBO and TETRA radios, so the final recommendation suits both the hazardous area and the people using the equipment every day.

To discuss two-way radio systems for hazardous or non-hazardous sites, visit the Radiocoms Two-Way Radios page and start a conversation with the team.

Let’s start a conversation.

Provide the following information and we’ll put you in touch with the right person.



    Radiocoms needs your permission to contact you in relation to your enquiry. Please consent below:

    By clicking submit below, you consent to allow Radiocoms to store and process the personal information submitted.

    Review our privacy policy.